We supplied four horizontal split-case pumps for the New Damietta pumping station (Egypt).
Two units handle filtered water transfer (330 L/s at 75 m head, 400 kW MV motors at 6.6 kV) and two units handle raw/turbid water transfer (550 L/s at 16 m head, 132 kW LV motors).
A key challenge was keeping NPSHr low for high flow in a negative-suction configuration—engineered and delivered.